Skip to content
Beatmung & Intubation
Medical supplies

Ventilation & Intubation

Choose from a wide range of high-quality products on the subject of Ventilation and intubation from renowned manufacturers such as Dräger, HUMMcGrath or Rüsch / Teleflex.

  • AEROway® Fast ZGA flow controller

    Original price € 124,62 - Original price € 318,26
    Original price
    from € 124,62 incl. VAT
    € 124,62 - € 318,26
    Current price € 124,62 incl. VAT
    HUM

    Single flow regulator according to DIN EN ISO 15002 ZGA plug with or without pressure hose Flow stepwise adjustable integrated inlet filter ...

    View full details
    Delivery: 1-2 working days
    Original price € 124,62 - Original price € 318,26
    Original price
    from € 124,62 incl. VAT
    € 124,62 - € 318,26
    Current price € 124,62 incl. VAT
  • AEROway® Fast-ZGA Dual Flow Regulator

    Original price € 347,04 - Original price € 527,45
    Original price
    from € 347,04 incl. VAT
    € 347,04 - € 527,45
    Current price € 347,04 incl. VAT
    HUM

    for oxygen, compressed air or with neutral marking Connection to DIN couplings or wall sockets according to DIN EN ISO 15002 Input: ZGA plug DIN 1...

    View full details
    Delivery: 1-2 working days
    Original price € 347,04 - Original price € 527,45
    Original price
    from € 347,04 incl. VAT
    € 347,04 - € 527,45
    Current price € 347,04 incl. VAT
  • AEROtube® disposable endotracheal tube sets (10 pieces)

    Original price € 37,81 - Original price € 44,33
    Original price
    from € 37,81 incl. VAT
    € 37,81 - € 44,33
    Current price € 37,81 (€ 4,43/St) (€ 4,43/St) (€ 3,78/St) (€ 4,43/St) (€ 4,43/St) (€ 3,78/St) (€ 3,78/St) (€ 3,78/St) (€ 3,78/St) incl. VAT
    HUM

    Sets with endotracheal tubes size 5 - 9 incl. guide rod and blocker syringe Type Magill with Murphy eye 15 mm ISO connector Control marker and bal...

    View full details
    Delivery: 1-2 working days
    Original price € 37,81 - Original price € 44,33
    Original price
    from € 37,81 incl. VAT
    € 37,81 - € 44,33
    Current price € 37,81 (€ 4,43/St) (€ 4,43/St) (€ 3,78/St) (€ 4,43/St) (€ 4,43/St) (€ 3,78/St) (€ 3,78/St) (€ 3,78/St) (€ 3,78/St) incl. VAT
  • AEROtube® mask stand for CPAP masks

    Original price € 23,64 - Original price € 23,64
    Original price
    € 23,64 incl. VAT
    € 23,64 - € 23,64
    Current price € 23,64 incl. VAT
    HUM

    Mask stand for storage of CPAP masks suitable for almost all CPAP masks, nasal masks, full-face masks also suitable for drying after cleaning adju...

    View full details
    Delivery: 1-2 working days
    Original price € 23,64 - Original price € 23,64
    Original price
    € 23,64 incl. VAT
    € 23,64 - € 23,64
    Current price € 23,64 incl. VAT
  • AEROway® pressure reducer with additional outlets

    Original price € 334,13 - Original price € 458,74
    Original price
    from € 334,13 incl. VAT
    € 334,13 - € 458,74
    Current price € 334,13 incl. VAT
    HUM

    Pressure reducer according to DIN EN ISO 10524-1 suitable for portable and mobile oxygen equipment Body made of nickel-plated brass available ...

    View full details
    Delivery: 1-2 working days
    Original price € 334,13 - Original price € 458,74
    Original price
    from € 334,13 incl. VAT
    € 334,13 - € 458,74
    Current price € 334,13 incl. VAT
  • AEROway® Fine double flowmeter for oxygen with color-neutral marking

    Original price € 340,40 - Original price € 340,40
    Original price
    € 340,40 incl. VAT
    € 340,40 - € 340,40
    Current price € 340,40 incl. VAT
    HUM

    ZGA connector DIN 13260 complies with DIN EN ISO 15002 Connection to DIN couplings pressure compensated, continuously adjustable flow Outlet: UNF ...

    View full details
    Delivery: 1-2 working days
    Original price € 340,40 - Original price € 340,40
    Original price
    € 340,40 incl. VAT
    € 340,40 - € 340,40
    Current price € 340,40 incl. VAT
  • AEROway® Fine double flowmeter for oxygen

    Original price € 340,40 - Original price € 532,27
    Original price
    from € 340,40 incl. VAT
    € 340,40 - € 532,27
    Current price € 340,40 incl. VAT
    HUM

    pressure compensated flowmeter according to DIN EN ISO 15002 ZGA connector DIN 13260 precise, constant flow infinitely variable flow body mad...

    View full details
    Delivery: 1-2 working days
    Original price € 340,40 - Original price € 532,27
    Original price
    from € 340,40 incl. VAT
    € 340,40 - € 532,27
    Current price € 340,40 incl. VAT
  • AEROway® Fine-ZGA AIR Dual Flowmeter

    Original price € 340,40 - Original price € 460,81
    Original price
    from € 340,40 incl. VAT
    € 340,40 - € 460,81
    Current price € 340,40 incl. VAT
    HUM

    Flowmeter as double version for compressed air (according to DIN EN ISO 15002) available with different AIR flows Flow continuously adjustable...

    View full details
    Delivery: 1-2 working days
    Original price € 340,40 - Original price € 460,81
    Original price
    from € 340,40 incl. VAT
    € 340,40 - € 460,81
    Current price € 340,40 incl. VAT

Mechanical ventilation

Mechanical ventilation or assisted ventilation is the medical term for artificial ventilation, in which mechanical means are used to support or replace spontaneous breathing. This can be a device called ventilation device, or breathing can be supported manually by a correspondingly qualified specialist, such as an anesthetist, respiratory therapist or paramedic, by pressing a bag valve mask.

Mechanical ventilation is called "invasive" when it affects an instrument within the trachea through the mouth, such as an endotrache alubus or skin, such as a tracheostomy tube. Facial or nose masks are used for non-invasive ventilation in the case of non-selected non-unconscious patients.

The two most important types of mechanical ventilation are the overpressure ventilation, in air (or another gas mixture) through the airways into the lungs, and the vacuum ventilation, in which air is essentially sucked into the lungs by stimulating movement of the breast. Apart from these two main types, there are many specific types of mechanical ventilation, and their nomenclature has been revised over the decades in the course of the continuous further development of the technology.

 

When does a patient have to be ventilated?

Mechanical ventilation is indicated if the patient's spontaneous breathing is not sufficient to maintain life. It is also used as prophylaxis if the collapse of other physiological functions or ineffective gas exchange in the lungs is also used. Since mechanical ventilation only serves to support breathing and does not heal an illness, the basic state of the patient should be identified and treated in order to solve it over time. In addition, further factors must be taken into account, since mechanical ventilation is not uncomplicated.

In general, mechanical ventilation is used to correct blood gases and reduce breathing work.

 

The usual medical indications for the application include:

  • Acute lung damage, including acute respiratory nympia (ARDS) and trauma.
  • Apnea with respiratory arrest, including cases of intoxication
  • Acute heavy asthma that requires intubation.
  • Acute in chronic airway acidosis, most often in chronic obstructive lung disease (COPD) and obesity hypoventilation syndrome.
  • Acute respiratory acidosis with carbon dioxide partial printing (PCO2)> 50 mmHg and ph <7.25, which can be attributed to paralysis of the diaphragm by the Guillain-Barré syndrome, myastenia gravis, motor neuron diseases, spinal cord injuries or the effect of naxwork and muscle relaxation.
  • Increased breathing work, as shown by significant tachypnea, retraction and other physical signs of shortness of breath.
  • Hypoxemia with arterial oxygen partial pressure (PAO2) <55 mm Hg with an additional proportion of inspired oxygen (FIO2) = 1.0
  • Hypotony including sepsis, shock, congestive heart failure
  • Neurological diseases such as muscular dystrophy and amyotrophic lateral sclerosis (ALS)

 

Risks:

  • Barotrauma - Lung baro trauma is a well -known complication of mechanical overpressure ventilation. This includes pneumothorax, subcutaneous emphysema, pneumomediatinum and pneumoperitoneum.
  • Ventilation -associated lung damage - Beating -associated lung damage (vali) relate to acute lung damage that occurs in mechanical ventilation. It cannot be distinguished clinically from acute lung injury or acute respiratory nympia (Ali/ARDS).

 

Complications:
Mechanical ventilation is often a life -saving intervention, but has potential complications such as pneumothorax, respiratory injuries, alveolar damage and breathing associated pneumonia. Further complications are membranetrophy, reduced cardiac volume and oxygen toxicity. One of the primary complications occurring in mechanically ventilated patients is the acute lung injury (ali)/acute respiratory nympia (ARDS). Ali/ARDS are recognized as significant contributions to the morbidity and mortality of the patients.

 

In many health systems, long -term ventilation as part of intensive care medicine is a limited resource (since there are only so many patients who can be cared for at any time). It is used to support a single failing organ system (the lungs) and cannot reverse a underlying disease process (e.g. cancer in the final stage). For this reason, there can be (occasionally difficult) decisions about whether it is suitable to start with mechanical ventilation. Just as many ethical questions concern the decision to cease mechanical ventilation.

 

The design of the modern overpressure fans were mainly based on technical developments in the military during the Second World War to supply the oxygen of fighter aircraft at great height. Such ventilation devices replaced the iron lungs because safe endotrachealt tubes with cuffs with high volume/low pressure were developed. The popularity of overpressure fans rose in Scandinavia and the USA during the polio epidemic in the 1950s and was the beginning of modern ventilation therapy. The overpressure by manual supply of 50% oxygen via a tracheostomy cannula led to a reduced mortality rate in patients with polio and respiratory paralysis. Due to the enormous personnel requirement for such manual interventions, mechanical overpressure fans have become increasingly popular.

 

Overpressure ventilation devices work by increasing the patient's respiratory pressure through an endotracheal or tracheostomic hose. The overpressure lets air flow into the airway until the ventilation of the ventilation device is over. Then the respiratory pressure drops to zero, and the elastic recoil of the breast wall and lungs press the tidal volume - exhalation through passive exhalation.

 

The time of withdrawal from mechanical ventilation - also called weaning or weaning - should be carefully weighed. Patients should consider their ventilation for the withdrawal if they are able to support their own ventilation and oxygen supply, and this should be assessed continuously. There are several objective parameters that you have to look for if you think about a withdrawal, but there are no specific criteria that generalize themselves to all patients.

 

One of the main reasons for the admission of a patient to an intensive care unit is the implementation of mechanical ventilation. The monitoring of a patient in mechanical ventilation has many clinical applications: improvement in understanding pathophysiology, help in diagnosis, guidance for patient management, avoidance of complications and evaluation of trends.