Erler Zimmer Interactive ECG simulator for R10052 in detail
Product description of the interactive ECG simulator for R10052
The interactive ECG simulator for R10052 allows you to trigger a defibrillation shock using a manikin or the simulator. You can also practise with your defibrillator/external pacer without a manikin by connecting the defibrillator/external pacer to the simulator using adapters. An inbuilt circuit allows you to pac directly into the simulator and monitor the ECG rhythms via the PADS connector. The simulator also has a conversion function that allows you to select a different rhythm immediately after the defibrillator is discharged. You can use any commercially available defibrillator for pacing. To save energy, the simulator is automatically switched off when not in use.
Product information "Interactive ECG simulator for R10052":
- Defibrillation shock can be triggered via manikin or simulator.
- Practise with your defibrillator/external pacer without a manikin. Connect the defibrillator/external pacer to the simulator using adapters.
- An in-built circuit allows you to pac directly into the simulator and observe the ECG rhythms via the PADS connector.
- Conversion function
- Select a different rhythm to be applied immediately after the defibrillator is discharged.
- You can use any commercially available defibrillator for pacing.
- The battery-saving function switches the simulator off automatically when not in use.
Rhythm types for pacing:
- Sinus bradycardia
- Junctional bradycardia
- Type 1 2nd degree AV block
- Type 2 2nd degree AV block
- Type 2 2nd degree AV block with ventricular extrasystoles (VES)
- Type 3 AV block. Grade 1
Adult/pediatric rhythms (17 in total):
- Ventricular fibrillation
- Ventricular tachycardia (fast)
- Ventricular tachycardia (slow)
- Ventricular tachycardia (polymorphic)
- Atrial fibrillation
- Atrial flutter
- Supraventricular tachycardia
- Sinus tachycardia
- Sinus rhythm with ventricular extrasystoles (VES)
- Asystole
- Normal sinus rhythm
- Sinus bradycardia
- Junctional bradycardia
- AV-Block 2. Grade 1 AV block
- Grade 2 AV block type 2
- Grade 2 AV block type 2 with ventricular extrasystoles (VES)
- Grade 3 AV block
The simulator also allows you to derive realistic 3- or 4-channel ECGs. The signal morphologies for the right and left arm as well as the left leg ensure precise visualisation of the QRS, P and T axes. The simulator is powered by a 9-volt alkaline battery and weighs 0.8 kg.
Ideally suited for
- Hospitals
- Healthcare centres
- Training facilities
- Research facilities
Advantages
- Interactive ECG simulator for R10052 enables defibrillation shock via manikin or simulator
- Exercise without manikin by connecting to external defibrillator/pacer
- Built-in circuit enables direct pacing and observation of ECG rhythms