Skip to content

Erler Zimmer Abdomen phantom child for CT, X-ray and radiotherapy

Original price $21,005.00 - Original price $21,005.00
Original price
$21,005.00 no VAT included
$21,005.00 - $21,005.00
Current price $21,005.00 no VAT included
Current price $16,902.02 excl. VAT
  • Highly realistic simulation of an abdomen with contrast medium
  • Realistically represents tissue contrasts in X-ray imaging
  • Includes the abdomen from the tenth thoracic vertebra to the base plate of the fourth lumbar vertebra
  • Manufactured with the latest technologies from real patient data
  • Realistic representation of bones, vessels and soft tissues
  • Can be calibrated to different tube tensions
  • Reliable and realistic ability to simulate the abdomen with flat vertebrae
SKU 11183
GTIN: 4250395324618
PZN:
Manufacturer part number: NLP1110
Product description

Erler Zimmer Abdominal Phantom Child for CT, X-ray and radiotherapy in detail

The "Abdominal Phantom Child for CT, X-ray and radiotherapy" is a highly realistic simulation of an abdomen with contrast medium (portal venous phase) of a child with a flat vertebra (first lumbar vertebra). The phantom realistically depicts tissue contrasts in X-ray imaging. It includes the abdomen from the tenth thoracic vertebra to the base plate of the fourth lumbar vertebra, including the complete liver and both kidneys.

This phantom is produced from real patient data using the latest technologies. Bones, vessels and soft tissue are authentically represented and have realistic CT values for all tissues at a tube voltage of 120 kVp in CT. If the phantom is to be used primarily at a different tube voltage (e.g. 100 kVp), the CT values can be calibrated accordingly on request. It produces realistic tissue contrasts in X-ray imaging. Air spaces in the phantom are filled with a material that has approximately -80 Hounsfield units.

With a size of 20x16x12cm, the "Abdominal Phantom Child for CT, X-ray and Radiotherapy" is a reliable and realistic way to simulate the abdomen of a child with a flat vertebra in medical imaging.

Advantages

  • Highly realistic simulation of an abdominal cavity with contrast medium
  • Realistically depicts tissue contrasts in X-ray imaging
  • Covers the abdomen from the tenth thoracic vertebra to the base plate of the fourth lumbar vertebra

Scope of delivery

  • 1 x Erler Zimmer abdomen phantom child for CT, X-ray and radiotherapy

Original price $21,005.00 - Original price $21,005.00
Original price
$21,005.00 no VAT included
$21,005.00 - $21,005.00
Current price $21,005.00 no VAT included
Current price $16,902.02 excl. VAT
Volume discount
Amount Discount Price
2+ 3% $20,374.85
4+ 5% $19,954.75

Delivery: 1-2 working days

Free returns

Trusted Shops buyer protection

Klarna purchase on account

Erler Zimmer Abdominal Phantom Child for CT, X-ray and radiotherapy in detail

The "Abdominal Phantom Child for CT, X-ray and radiotherapy" is a highly realistic simulation of an abdomen with contrast medium (portal venous phase) of a child with a flat vertebra (first lumbar vertebra). The phantom realistically depicts tissue contrasts in X-ray imaging. It includes the abdomen from the tenth thoracic vertebra to the base plate of the fourth lumbar vertebra, including the complete liver and both kidneys.

This phantom is produced from real patient data using the latest technologies. Bones, vessels and soft tissue are authentically represented and have realistic CT values for all tissues at a tube voltage of 120 kVp in CT. If the phantom is to be used primarily at a different tube voltage (e.g. 100 kVp), the CT values can be calibrated accordingly on request. It produces realistic tissue contrasts in X-ray imaging. Air spaces in the phantom are filled with a material that has approximately -80 Hounsfield units.

With a size of 20x16x12cm, the "Abdominal Phantom Child for CT, X-ray and Radiotherapy" is a reliable and realistic way to simulate the abdomen of a child with a flat vertebra in medical imaging.

Advantages

  • Highly realistic simulation of an abdominal cavity with contrast medium
  • Realistically depicts tissue contrasts in X-ray imaging
  • Covers the abdomen from the tenth thoracic vertebra to the base plate of the fourth lumbar vertebra

Ideally suited for

  • Hospitals
  • Healthcare centres
  • Training facilities
  • Research facilities

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

You might also like this