Erler Zimmer Dog head - phantom for CT and X-ray

Original price $10,353.00 - Original price $10,353.00
Original price
$10,353.00 no VAT included
$10,353.00 - $10,353.00
Current price $10,353.00 no VAT included
Current price $8,349.00 excl. VAT
  • Authentic simulation of a dog's head without contrast medium
  • Representation of bone and soft tissue
  • Realistic CT values at 120 kVp tube voltage
  • Air spaces with cellulose polymer composite
  • Adaptation of CT values possible at other tube voltages
  • Realistic tissue contrasts in X-ray imaging
  • Size: 14x13x22cm
SKU 11754
GTIN: 4250395327374
PZN:
Manufacturer part number: VET14010
Product description

Erler Zimmer dog head phantom for CT and X-ray in detail

The phantom offers you an authentic simulation of a dog's head without the use of contrast agents. Both bone and soft tissue are realistically represented, with all tissues showing realistic CT values at a tube voltage of 120 kVp in CT. The air spaces are filled with a cellulose polymer composite that has a Hounsfield value of approximately -80. If you wish to use the phantom mainly at other tube voltages (e.g. 100 kVp), the CT values can be calibrated accordingly if required. The phantom also provides realistic tissue contrasts in X-ray imaging.

Size: 14x13x22cm

Advantages

  • Authentic simulation of a dog's head without contrast agent
  • Representation of bone and soft tissue
  • Realistic CT values at 120 kVp tube voltage

Scope of delivery

  • 1 x Erler Zimmer dog head - phantom for CT and X-ray

Original price $10,353.00 - Original price $10,353.00
Original price
$10,353.00 no VAT included
$10,353.00 - $10,353.00
Current price $10,353.00 no VAT included
Current price $8,349.00 excl. VAT
Volume discount
Amount Discount Price
2+ 3% $10,042.41
4+ 5% $9,835.35

Delivery: 1-2 working days

Free returns

Trusted Shops buyer protection

Klarna purchase on account

Erler Zimmer dog head phantom for CT and X-ray in detail

The phantom offers you an authentic simulation of a dog's head without the use of contrast agents. Both bone and soft tissue are realistically represented, with all tissues showing realistic CT values at a tube voltage of 120 kVp in CT. The air spaces are filled with a cellulose polymer composite that has a Hounsfield value of approximately -80. If you wish to use the phantom mainly at other tube voltages (e.g. 100 kVp), the CT values can be calibrated accordingly if required. The phantom also provides realistic tissue contrasts in X-ray imaging.

Size: 14x13x22cm

Advantages

  • Authentic simulation of a dog's head without contrast agent
  • Representation of bone and soft tissue
  • Realistic CT values at 120 kVp tube voltage

Ideally suited for

  • Hospitals
  • Healthcare centres
  • Training facilities
  • Research facilities